Dynatec Systems has provided a 2 MGD (million gallons per day) tubular Ultrafiltration (UF) Membrane Bioreactor (MBR) to process dairy wastewater. 

The system is a conversion of an existing extended air system where an existing bioreactor is being utilized.  The capacity of the existing bioreactor will be doubled with an increase in the mixed liquor solids concentration and an upgrade of the fine bubble aeration to slot injector aeration.  

Dynatec Systems has provided a leachate treatment system for a hazardous waste landfill. 

Dynatec Systems has provided a leachate treatment system for a hazardous waste landfill.  The system incorporates heavy metals pretreatment followed by a tubular Membrane Bioreactor (MBR) system.  The Membrane Bioreactor (MBR) reduces ammonia, phenol, Polychlorinated Biphenyl (PCB), Chemical Oxygen Demand (COD), volatiles and semi-volatiles and other contaminants adequately for discharge.  The system reduces PFAS 30-60% and carbon is utilized to reduce PFAS to low ppt concentrations.

Dynatec Systems has provided a zero-liquid discharge (ZLD) wastewater

Dynatec Systems has provided a zero-liquid discharge (ZLD) wastewater treatment system for a food processing company. The primary treatment is provided by a tubular Membrane Bioreactor (MBR) followed by Reverse Osmosis (RO). Membrane Bioreactor (MBR) permeate is reused for cooling tower make up. Reverse Osmosis (RO) permeate is used for high-quality users and Reverse Osmosis (RO) reject is used for irrigation.

Dairy converts existing biological system to MBR

Dynatec converted an existing conventional biological treatment system at a dairy to a membrane bioreactor (MBR). The converted plant has the ability to process wastewater at the rate of 475,000 gallons per day.

Cheese Processing Plant Gets HiRate MBR UF

Dynatec Systems will install another HiRate™ UF for MBR service to process 400,000 gallons per day for a cheese processing plant.

UF System Removes Oil & Metals

Automotive parts manufacturer needed a UF system to remove oil and metals to allow the treated water to be acceptable for discharge.

Automotive Connectors Manufacturer

A leading manufacturer of quick connectors for transfer of engine oil cooling fluids was in need of a wastewater treatment system to address oil and grease and heavy metal contaminants in their discharge. Based on understanding of the waste stream and ability to provide a cost effective solution, Dynatec was selected to provide a system that would produce effluent that reliably met the sewer discharge requirements.

Automotive Parts Manufacturer

An auto parts manufacturer was in need of a system to process 2,500 gallons per day of oily waste water. An ultrafiltration system was selected based upon its ability to consistently meet the discharge requirements without chemicals and limited operator involvement. This ultra filtration system removes oil and allow zinc in compliance with discharge requirements.

Anaerobic digester and Aerobic MBR followed by reverse osmosis for whiskey Manufacturer

A whiskey manufacturer needed a wastewater treatment system to reduce the very high organic content (BOD and COD) as well as the solids content (TSS) of the wastewater stillage to achieve the demanding final treated water discharge standards.